Sally Eggleston, MBA
COO
Radiation Business Solutions, USA

Transcript

I’m Sally Eggleston. I work for Radiation Business Solutions. I’ve probably talked to quite a few of, if not you, somebody in your system. We assist Vision RT’s customers with reimbursement questions and payer problems. We’ve been in the business over 22 years with radiation oncology. It is our passion. It’s what we do. We’re a full revenue cycle, but we like to help people. We own and operate and manage centers also, so we understand the pains and what you guys go through on every day, and radiation oncology is really at a very important time right now. So one of the things you will hear me preach is continue to fight and work with these payers.

Just a small disclaimer: your practice is your practice. You need to do what you feel right and document the heck out of everything. So this is what happened to us in 2026. These are the descriptors. When you look at 77412, it specifically says there are different caveats. There’s either multiple isocenters, or the single isocenters with active motion management, which is what a lot of what we’re talking about today, or total skin, or mixed electron photon. So one of the things that I’m going to talk about here shortly is about the fact that there are so many variables that are in there. And this is the payment rate that we’re looking at. The top is the Medicare physician fee schedule, which would be freestanding, and below that would be the hospital outpatient. And you can see that there are definitely discrepancies in there, and that’s one of the things that we’ve got to get addressed.

Probably one of the surprisingly biggest issues that we hear people talking about is this 77387, and I don’t really understand it, but hospitals and coders are really having a problem with that from the standpoint of, they don’t understand it. They don’t believe it’s still billable. They think it is packaged in the treatment delivery, which it is on the technical side, but it’s not on the professional side. Your physicians should be billing the 77387 if they are doing anything such as cone beam CT, SGRT, and looking at images, stereoscopic, any of those. So, if you’re having issues with your system or somebody with that, please reach out to us because that is craziness for our physicians to not get RVUs and payment for that code on a daily basis.

So some of the common questions we see are that, can we do it? Yes, you can. Let’s get that one going. Active motion management: whenever those CPT codes had the new descriptors, the first thing we did was look at what the AMA’s and the CPT definition was, and if you read that, it clearly states surface guidance in there. It says, example: intra-fraction motion, surface guidance to monitor the target or organs at risk during the breathing cycle. Example: it minimizes organ motion, allows more accurate delivery to mobile targets. It’s a technique that can provide gating using the body surface contouring as a surrogate for internal target motion, using the surface as a surrogate for internal motion. So that solidified to a lot of people like Dr. Jones and to us as we read it, that surface guidance is in the descriptor. It accounts for active motion management. It is billable under the 77412.

I’m not going to talk a lot about medical necessity because Dr. Jones did an amazing job with that. That is always the case. Documenting medical necessity from the physician’s standpoint—I can’t tell a physician how to treat a patient. None of us can in here. Only a radiation oncologist makes that decision. So it is up to them to document why they are doing active motion management with whatever technology they’re utilizing, and in this case, SGRT, through Vision RT. So, those orders must be in there, and a lot of this when it comes to commercial payers, is about that documentation and what you say to get your authorization, and we’ll talk a little bit about payer issues in a minute. So it does need to be patient-specific. You can have a rather canned paragraph, but dropped in patient-specific information is strongly encouraged.

And the patient must be monitored during beam-on. Surprisingly, we still get asked that question, too. So it’s not about setup, it’s about monitoring during beam-on, and we just had the conversation; that was straight from Emilio from ASTRO, who is really championing on the coding side for all of us that surface guidance does qualify for active motion management under 77412. There’s that question over and over again. Yes, it does. It’s one of several. So that’s the other thing, right? I’m on an island here. It’s not just one technology, it’s more than one. They’re very clear with that. But Vision RT definitely hits the mark.

And this utilization question continues to come up. You just heard what Dr. Jones’ was. And the way the utilization—the reason that comes up—is because in the proposed rule and in the final rule, there were percentages of how much percent of the Level One, Level Two, and Level Three treatment delivery that was expected. And they do that because they have to do that because there’s just one bucket of money for everything under the Medicare physician fee schedule, and they have to allot these dollars of how they think it will work, and that’s how they decide on payment. And that’s why we saw payment fluctuation from the proposed rule to the final rule.

So those percentages are in there because of that, but does that mean that’s what you should do or where you should be or that you should worry about that? And our response to that is always no. And when I read that 77412 descriptor, how would they even know if you were a center in a rural area who treated 50% of their patients with bone mats that have more than one isocenter versus you doing surface guidance, active motion management, right? A payer’s not going to know that. CMS is not going to know that. So their data mining of utilization is going to be all over the place strictly because of the wording in that descriptor. So, keep that in mind. It’s difficult whenever there has to be a decision tree for you to make for your therapist to figure out what code it should go to, right? At the very beginning, that’s what we utilized. It worked well, but that’s craziness, right? That’s where we end up having to do.

We do have resources for Vision RT customers to help you on the authorization side, appealing a claim. Radiation oncology has to stick together right now. This is not the time to roll over or allow your physician to say, “EviCore, I don’t want to do a peer-to-peer.” This is not the time to do that. We’re really at a crux here. It’s not just the freestanding centers that are feeling this, but hospitals also. So it is definitely the time to band together.

When it comes to these codes, it’s difficult, and somebody asked the question, have you got any Medicare denials? Medicare is going to pay you most of the time for whatever code you send through. They don’t know what you did. It is an honor system, right? Which is why you document thoroughly. It’s why you put everything out there. Make sure that you’ve ordered medical necessity and you’ve documented what you’ve done. If Medicare does anything, it’s on the back end and they may say, they periodically look at a center and say, “We need 10 medical records to prove that you did this.” CERT audits and those type things.

When it comes to the commercial payers, different story. So because in the freestanding centers we had been utilizing G-codes for over 10 years, right? We’d been using G-codes for a long time. So in November, we’re calling commercial payers and saying, “We want to make sure you’re prepared. We’re going to not be billing these G-codes.” These are old CPT codes. They’re not new. I used these a million years ago. Dr. Tannahill’s talk really spoke to me yesterday because I’ve been saying that for a long time. We’re totally flipping back to the old school days, right? So when you have CPT codes that have been on a commercial payer’s fee schedule for a really long time, they just keep lowering what that payment rate is. And so what happened come January, yeah, they’re processing your new CPT codes, but the rate is really low. So there’s been a lot of battles to fight. There’s been updating your fee schedules.

The Medicaids, and I kind of laugh about this, and I’m not poking fun at ACRO, don’t think I am, because we work with ACRO and ASTRO to make sure that they are advocating on our behalf all the time. They put this list up on a webinar that they had last week. There were some duplicates on there. Well, this is how many payers and the states that they had been working with. We’re a revenue cycle company that has been in the business for 22 years. So we looked at our system. We had 741 payers in there. That’s a lot, right? So, this has been our problem. Freestanding centers, a lot of times, don’t have the manpower to go to those commercial payers, make sure the fee schedules get updated. Hospitals don’t pay attention, frankly. Right? So, sorry, but that’s the reality of the revenue cycle side in a hospital. And it’s really important right now for hospitals to be adjusting their charge master with these codes. Because that utilization, what the cost is, goes to Medicare, and we got to make sure we have that part right.

So there’s still a lot of work to be done. Every Medicaid in the United States has got a letter from ASTRO and ACRO and from us, and any place we have a client, we’re sending letters to the governors, to state officials, because Medicaids are state-run, and they’re not wanting to pay for these codes because they don’t know what to do with it. I’m not quite ready for questions. I just wanted to throw out, ASTRO did have a town hall Wednesday night. It was supposed to last an hour and a half. It just lasted an hour 15 minutes. It was pretty low-key. They explained what happened, what they’ve been doing, everything from their Hill day last week to working with payers to trying to get a fix or a change. I’ll be blunt, it doesn’t look promising. And the reason being because come July, our proposed rules are going to come out, and it’ll be interesting to see where our payment rates lie there. They did say very specifically, because somebody asked, “Are prostate patients 77470 level two?” The answer was yes. And then another physician on ASTRO chimed in and said, “But we need to keep in mind that if they have the technology and can provide active motion management, that they are 77412.” That came out of their mouths. Everybody heard it. Unfortunately, there was at the max, 110 people on that Zoom call, which is very disappointing to me for this industry. There again, now’s the time. We’ve got to band together. We’ve got to advocate.

The other thing that they stated on there was that they will be putting out a policy, but it probably will be the summer, which is rather unfortunate that we get the policy July, August. I figure they’re probably waiting a little bit for the proposed rule to come out there, too. But that was the latest and greatest from them. It solidifies what we and Vision RT have been telling their customers. That goes right along with what Dr. Jones said. If you have the medical necessity from the physician, you’re documenting it, then bill your 77412, your level three.

On some payer notes, UHC, they’re difficult. That’s just all there is to it. They are still wanting to deny a lot of prostate and brains, and we’re talking about getting the authorization up front. But they definitely deny for the first level, and you have to move on and keep fighting, which you can have a bit of success. eviCore did publish guidelines, so they become pretty clear. They consider peer-to-peer outside of anything that’s not on their covered diagnosises. ASTRO worked with them in early January on that, and most of the time, we can get 77412 approved outside of their diagnosises today. Carelon, which is a radiation benefit management company, all body areas are okay for 412, but based on individual plan guidelines, so you may have to argue some of those. Evolent denies head and necks, and their medical director told us that they have been instructed to deny prostate. So I don’t know, Dr. Jones, if you’re seeing that with any payers that Evolent is their benefit management company.

So we do have struggles, and some of these you are having to do peer-to-peers, your physicians are, but there again, don’t give up the fight. Keep after it, because it’s vital at this point in time. We’ve made strides with this 412 since January, I feel like, and ASTRO is helping along with that. So we don’t want to go backwards from that standpoint.

 

 

This transcript was generated using AI. If you note any issues, please email us at secretary@sgrt.org. 

Guy Jones, MD
Radiation Oncologist and Medical Director
Oncology Nevada, USA

Transcript

My name is Guy Jones. I’m a radiation oncologist and medical director for Oncology Nevada in Reno. I also have some clinics in several other states, including elsewhere in Nevada, in Las Vegas. It would seem like a different state, but it’s not, and Washington State, Alaska, et cetera. I want to talk about the clinical value of SGRT’s use in radiation therapy across all body sites. We are heavily pelvic, prostate specifically, but we treat all kinds of cancers and benign conditions in our clinics, and so this is used across the spectrum.

A little bit about Oncology Nevada: we are a freestanding physician-owned clinic in Reno. We have a very high-volume center where we treat anywhere between mid-60s to mid-80s on a single Varian TrueBeam, and about 70% of our cases are prostate. We have block times, they vary, but around 10 minutes. The way I got originally interested in Vision RT was when I was practicing in Washington State in the eastern side of the state. Anybody know the Tri-Cities? That’s where I’m from, that’s where I grew up, and that was my first job when I came out of training, and I was really interested in doing treatments for trigeminal neuralgia, like stereotactic ablation procedures. We had a Varian Edge at the time, and we could use a virtual cone to treat, in theory, but really it hadn’t been justified to treat trigems using a non-invasive system and with just surface guidance. So I started that program in the Tri-Cities about maybe eight years ago and treated about 100 trigems over a couple of years there. So I was really kind of surprised how much volume we had. And then we wrote up our paper for a stereotactic conference, and we were giving 90 gray in a single shot to that nerve root of the trigeminal nerve just right next to the brain stem using SGRT. And it worked. We had really essentially no toxicity and good outcomes comparable to anything else out there, CyberKnife, Gamma Knife, et cetera. So it got me really interested and confident in the technology, and so when I came to Reno, I not only deployed this at our site in Reno, but also across our other centers that I either own or am affiliated with.

There’s a lot of benefits to SGRT, and I’ll go through them in no particular order. But I’d say one of the big ones is just being able to get away from tattoos and having just markerless treatments. So it seemed like a small thing. Actually, patients do value it a lot more than you would think they do. And there’s a lot of reasons for that. There’s psychological reasons, et cetera, but it is also more accurate to not line up just on small little points, but to do it over a stretch of the body. And that’s essentially what SGRT allows you to do, specifically the Vision RT system.

So what we have found—well, not just us, but in the papers—they’ve shown that it reduces the shifts that are done. It also reduces the treatment time, and it reduces the amount of additional imaging you have to do. So, when you do your initial IGRT, you do the setup, you just don’t have to reshoot the images that often. In fact, it’s about a two-thirds decrease in the amount of re-imaging you have to do, which is something we always document, and it isn’t considered necessarily a medical event, but it’s something we keep track of, and it is important to reduce patient radiation exposure. It’s just that general ALARA principle we all talk about.

I love the way the interface is on this. And one thing I want to just back up a little bit and say is that our center, you can imagine, if we’re treating 60 to 80 patients a day on a single machine, and our manager, supervisor, therapist is in the room, the first thing they brought to me and asked, and the first thing I asked this company was, “Can we ensure that this is not going to increase our treatment times? Because we cannot reduce throughput.” You add a minute a day, you’re there for another hour and a half. You can’t do it. So it needs to be at least neutral, if not a time savings. And we put it in, and we’ve seen exactly that, which is exciting, and that’s been true across our centers. One of the things I found kind of interesting is that they removed SGRT as a reimbursable part of SBRT treatment, and yet when I gave the option to my therapist saying, “Well, we’re not going to get paid for this, so you don’t necessarily have to do it for SBRT,” they said, “No, we’re going to keep using it because we like it and it helps us set up better.” So it was kind of proof of principle. At first, it was like having to pull teeth to get them to do it, and then once they started doing it, it was like, hey, I can’t really take it away from them. So I think that shows a lot.

So a couple of different things. You guys all know this. This is maybe not the best audience for these messages, but this is for intrafraction motion management as opposed to interfraction motion management. This isn’t setup. And that needs to be clearly documented in your medical necessity so that we’re not talking about just another IGRT. If it worked the same as IGRT, you’d just use IGRT, or you’d just use this, one or the other. But it’s two different things. One is what you’re setting up to initially, and then after that you’re going to… Are you guys hearing feedback, by the way? This is throwing me off a little bit.

Yeah. All right. I don’t really know what to do about that. Maybe step back a little bit or move up. That’s better, isn’t it? Sorry. You want me to start over? So, this is actually relevant across disease sites. So not only do we have it for prostate and pelvic… I’m still getting the feedback. Is everybody still… There’s something wrong with the electrical in this room. All right. Is it tolerable? Can we just go on with it? Okay. All right. I’ll just do that. So again, we treat a ton of prostate, we treat a ton of pelvic aside from that. We’re treating pelvic lymph nodes, and then especially for abdominal targets, frankly, I would not be comfortable without some strict motion management if I was treating SBRT pancreas. I need that for something like that. So, there are certain things where it’s just an absolute must, and it’s most important, ironically, for SBRT, which is where this code got pulled out as a separate billing code. Which is counterintuitive, but why does CMS do half what it does?

One thing to keep in mind is that we’re not—and a lot of people have talked about this—it’s like a thin line between, okay, we’re not really monitoring the tumor, we’re monitoring the surface of the body. Those are two different things. Well, it is and it isn’t. It’s a surrogate. It’s no different than when we used to set up just on the skin and then maybe had some crude imaging, old MV films, for instance, and you couldn’t see hardly anything, and you’re kind of hallucinating it. But you’re still tracking. You’re setting it up based on external anatomy. So, it’s essentially the idea that external anatomy does correlate with internal anatomy, which is common sense, but at the same time, it’s something that’s been brought up as maybe two distinct things. They are essentially one and the same. When you monitor the body, you are using that as a surrogate for the internal anatomy, and that’s the reason this works. Along with tattoo-less delivery, the reduction in the treatment times, fewer shifts, less repeat cone beams, things like that.

So again, it’s not just for positioning, it’s continuous intrafraction motion that is really what makes this important and makes you be able to give a clinical case for the billing case, which unfortunately is a reality that we all face. Again, sub-millimeter accuracy. We have reduced setup errors and less re-imaging, real-time motion tracking without immobilization, faster setup, and then the tattoo-less options. And all these things have been clinically documented. These are all peer-reviewed PubMed articles that are in my clinical justification document that I put in for every patient that we’re doing SGRT on.

The final rule that came out—well, it’s not a rule anymore. I guess this is an older slide. It is the final rule, but it’s now the current rule. This 77412, as many times as we can capture that, the better. Obviously, we all took a hit this year. This was a big mess. It’s still a big mess, and we’re sorting it out. But I would say that it definitely, in terms of Medicare CMS, that very much the SGRT fits what the spirit of this idea of why we should be able to justify 77412. But we found even most of the commercial payers, aside from a couple of problem children, the normal ones, United and Blue Cross, they are paying it. And I think we’re capturing over 90% 412 in a couple of our markets, but not all of them. So your market may vary.

The key to reimbursement on this, though, is to have any chance of it and frankly, to reduce the chance of an audit or anything like that, is you do need the clear documentation of SGRT use. And then you also need the justification through a letter of medical necessity that we upload, and that’s how we’ve been doing it for several years now. I should say, we’ve had Vision RT for maybe three years or so now. So it’s been a while, and we’re really glad we did it back then because we could get paid for it. Now, we’re just glad we have it so we’re not reduced in our current reimbursement because we’re getting so much 412.

So the things I put in my letter of medical necessity, my documentation of medical necessity, are that it’s utilized again for intrafraction motion. So again, to separate it from IGRT, that surface tracking is being used as a surrogate for internal target positioning. And I do say things like, if somebody coughs, fidgets, or any otherwise adjusts, these are things that you want to just have that in there spelled out as some reasons we would want to use this. That there is beam held. The automatically part, that’s going to be interesting whether there’s any clarification on whether it has to be automatically held or whether you can just set a tolerance and watch it. Right now, it doesn’t seem to matter, and based on some discussions with some of the higher-ups in ASTRO leadership, they didn’t think that it necessarily needed to be automatically integrated. And so except for one of our sites, we haven’t really been doing that. But just something to say, “Hey, the tolerance should be X amount.” Document that in your letter and in the simulation setup note, and then you should be good to go. And then you want to say that it’s required to maintain treatment accuracy and reduce the dose to OARs. That’s the whole point to this, is that you’re hitting the right spots and not hitting the things that don’t need to be hit. And then it allows reduction of PTV margin along that same idea.

For daily treatment documentation, this one’s nice because it’s essentially been done for us. Vision RT has an integration with ARIA, and it shows up in your offline review checks. So same place the IGRT images are popping up, there’s a form that’s automatically showing that we used SGRT that day. So it’s just one extra click of a button for each patient every day. It takes no time at all. So this was nice in that before the therapists were having to upload each individual one, fill out a form for each individual one, now it’s all just done automatically. So if you do get this system, I highly recommend you get the ARIA integration. And I don’t know if it’s available for the other—Is it like Mosaic too and others? I don’t even know. But it is? Okay, I’m getting a nod, so I think it is available for the others.

So the billing pitfalls, the things you absolutely need to make sure are not in your documentation are that you aren’t using the SGRT just for setup. In fact, we say not just for setup, using for intrafraction motion. Make sure that sentence is in there. You want to say that you’re beam-on monitoring. Again, a lot of that’s done for us through the ARIA integration, but it’s still just make sure it’s in your letter of medical necessity. You want to say some defined tolerances. Everybody’s going to say something different. You want to have, again, the statement of medical necessity uploaded alongside your clinical treatment plan and then, again, have it in ARIA somewhere permanently in case you ever get come back and get audited.

So again, the ARIA integration we talked about has made this really, really easy. You can see it’s just right up in the offline review on the bottom. It’s just one extra thing. Instead of an image, it pops up a document, just sign it. And this records all those things we were just talking about that need to be recorded.

Couple of things when you first integrate it, and like I said I did, whenever I bring something forward, and the therapists are really busy at our center. Most centers I know of, they’re really busy, and so these are things you’re going to have to… What we did is we just kind of found a champion therapist amongst the group and just said, “Hey, are you interested in this technology?” And she said, “Yeah, this sounds great.” And we just said, “Will you help us roll this out?” And she became kind of like a lead of this technology, and she’s been to a couple of the conferences and had a great time. But this is going to require some buy-in from the therapists, and you have to just let them know at first this is going to be a little frustrating, but then pretty quickly you’re going to get used to it. And I will offer our sites if there is any of your therapists that want to come take a look at how this is used in a high-volume center. I know Laura’s happy to have them at Reno. We’re happy to have them down in Vegas or any of our other sites if that would be something that would be helpful. Just let me know.

So the system QA does require some calibration. There’s some initial setup learning curve as there is with any technology. And then you need to make sure that integration and the ARIA documentation is going through, so there’s just an extra paperwork step that they need to at least make sure is in there. Fortunately, they don’t have to upload it manually like they used to. But again, it’s decreased treatment times across our center, which ultimately is something that they’ve valued, being able to get out a little bit earlier than before. And also we know we’re doing a little bit better for the patients as well.

So in conclusion, this is an active motion management system. It’s clinically validated, widely adopted, a lot of PubMed studies on it. Not just this technology, but a lot, but they’re all pretty similar. Supports precision, safety, and efficiency. Over 300 studies growing adoption. It used to be, I forget what, I think it was first used in the brain, and then over the next five or 10 years, it’s been now considered medically necessary for all body sites, including pelvis, and that’s in the peer-reviewed literature. And it gives us not only time savings but supply savings, staff savings, and then allows us to increase our throughput and provide a better quality of life for our patients and our staff. So really happy. I think this has been a big success story for our clinics.

 

 

This transcript was generated using AI. If you note any issues, please email us at secretary@sgrt.org. 

Sharon M Meredith, RT(R)(T)
Radiation Therapy Supervisor
Cape Fear Valley Health, USA

Transcript

So I was excited to be able to share my experience with using the AlignRT OIS Report module to assist with active motion management documentation. I work for Cape Fear Valley Health in Fayetteville, North Carolina. We have three locations, and at each location, we use Varian TrueBeams and then AlignRT for our SGRT patients. When we first started using it, we were predominantly only using it for just a handful of our patients, the deep inspiration breath hold breast patients. But as we have grown and evolved through the years, we’ve expanded that usage to encompass all types of treatments, and so currently we utilize SGRT for the majority of everyone under treatment. Our physicians are not only wanting us to use it for alignment and positioning in the room, but also to ensure that we have and monitor the patient’s position throughout treatment so we can ensure they’re in the correct position through the entire procedure.

So a daily basic run-through of one of our procedures would be to start off by using the AlignRT Patient ID module. This uses facial recognition software to ensure we have the correct patient in the treatment room, and then we’ll verify this with the patient by having them state their name, date of birth, the site that we’re treating. And then once we place them on the table, we will press play in AlignRT so that we can get them in the correct position before we ever even step out of the room. And then once we step out, we proceed with our daily imaging, which is typically cone beam CT for almost everyone, sometimes KV and MV. Then we’ll apply the shifts and capture the position in AlignRT, which essentially zeros out the deltas, so it defines our reference position for the day. The real-time deltas are the deviation between the patient’s current surface position and the reference surface position, which was attained at the time of CT simulation. And then we will toggle beam control on, and with beam control being toggled on, if that patient moves outside of the small parameters that we have set, the beam will be paused until they’re back in that threshold again, and then we’ll continue on with treatment. And then at the end of treatment, while that patient is still in that correct treatment position, we will pause the AlignRT screen so that this correct position is accurately reflected in the SGRT report for our physicians.

So the daily SGRT report is necessary for billing purposes, for documentation purposes. It has to be approved by a physician, typically within 24 hours or before that patient’s next beam-on time. Every department has their own way of documenting and recording their SGRT treatments, and at our site for years, we had a document that was created by our physicians. This is an example of one of our old documents in which we would input that daily treatment information. So it was created in ARIA, and it would appear in a list of documents for the physician to have to go in and approve. So at the completion of treatment, after we would pause that AlignRT screen, one of the therapists would sit down and type all those values into the document. They’d have to make sure that they tagged the correct physician into the document. Then they would have to select from a drop-down menu the type of treatment that we were performing for the day, like 3D, IMRT, VMAT, SRS, SBRT, and then they would type all those values from that pause screen into that document. And although effective, it did give us a form for approval. It was not the most efficient system. It would typically take 10 to 15 seconds, probably per patient, to type all that into the document. And although 15 seconds is not a very long period of time, if you have a busy schedule, 30, 35, which I thought was busy for us until I’m hearing some people have 60 to 80 patients a day, that really can start to add up. And there would always be at least once or twice during the day where one of us would be putting our values into the document, and one of the other therapists would think we were finished and would close that screen out to move on to the next patient. We’d have to stop what we’re doing, go back into the previous patient’s chart before we can bring the next patient in, pull up that document, and finish typing everything in. So sometimes not the smoothest system. The biggest issue, though, would be human error. It’s very easy, especially if you are in a hurry and you’re trying to get everything typed in before that next patient’s set up, to perhaps type in an incorrect value or leave a negative sign off, or leave a number out or put a decimal in the wrong spot. The biggest issue I would typically find would be that the therapists sometimes would forget to tag the physician into the document. So it might not get caught until the next weekly chart check, and we’d realize we had a document sitting there that never had gotten approved, and it was because the physician was never tagged into it and didn’t know it was waiting for their approval.

So around September of this past year, we were given the opportunity to be one of the test sites for the new AlignRT OIS Report module, and we were really excited to give it a try to see if it would help to improve our workflow, and it definitely has. AlignRT has always had the ability, although we were not doing it at the time, to be able to take a screenshot, convert it into a PDF, push it into a folder, and then manually export that into the oncology information system like ARIA or Mosaic. We use ARIA. But it was always a manual process. So now with the AlignRT OIS Report module, it’s a seamless transfer of information. It occurs entirely in the background. It takes that SGRT report and converts it into the DICOM format and then pushes it into the OIS automatically at the completion of treatment. So now when we complete one of our patients’ treatment and we pause and close that AlignRT screen out, this creates a screenshot of that final pause window. It inserts into the timeline in the RT summary in ARIA, and then it creates that AlignRT report. So we’re no longer having to tag a physician into the document. They’re not having to go into a list of documents to sign off on anything. I did ask our physicians if it makes it easier for them, and they did say that, yes, it makes it a bit quicker, more streamlined. They’re not having to go to two different locations to sign off on anything. It appears alongside the images they’re reviewing every day in the offline review. The therapists, of course, love it because it’s saving them a lot of time of having to manually enter in data after every single treatment, and of course, it’s helping to eliminate the risk of human error of typing those in incorrectly.

So the AlignRT report can be tailored and customized for each facility. This is an example of one of our patient’s AlignRT reports. Perhaps there’s something in the customization of our report that another site would not want to include, or perhaps we don’t have something included in ours that another site would want to include. It has all that basic patient information, name, date of birth, medical record number, the site that we’re treating, even though I don’t think you can see that because it’s probably darkened out with patient identifiers, but it is on there. It does include the screenshot of that final pause window, which was sent over from the AlignRT screen, and also it has the total duration of time, which is from when we open that patient up in AlignRT to when we close the patient out of AlignRT. It has a monitoring session time, so it breaks it down a bit further, and that’s from when we press play in AlignRT to when we pause and close out. So for this particular patient, that’s encompassing the alignment in the room, the imaging, and then the treatment itself. It includes the statement that the AlignRT system was used to position the patient immediately prior to treatment and track the patient during treatment in 3D mode. This is the default statement, and it can actually be customized as well, and some sites are now getting the verbiage to state that the patient is being tracked with active motion management. If we capture SSDs for the day, those will be inserted into the report as well, as long as we save them to the report, and that’s one of my favorite features of AlignRT in general. I love the fact that with the click of a mouse, I can capture SSDs from multiple treatment angles. So if we get those SSDs and save them, they will be inserted also.

So this is an example of a patient monitoring graph. We do not currently have this included or configured into the layout of our report at this time. I do think it’s a really neat feature, though. A lot of sites are not including it because it does increase the length of the report considerably from what I understand. As you can see, this is just a small example of one online and it says page one of eight, so it definitely increased the length of the report. But it’s a really neat feature, and it’s actually reflecting that patient’s motion and position throughout the entire treatment. If that patient ends up moving and the beam is held due to deltas being out of tolerance, that’s reflected in the graph. So as you can see on the graph, where the red bar dips below, that represents where the deltas were outside of the tolerance, and then the yellow bar represents where the beam was held due to the deltas being out of tolerance. So it’s another option. It could be included, and it would definitely be able to show evidence of performing active motion management.

If you have a patient with multiple sites, we’ve learned that we can create an AlignRT report with screenshots from each site on a single report. The physicians do seem to like this. It’s a little bit less they’re having to sign off on, and it’s fairly easy to do. So if you have someone with, for example, two sites, at the end of your first site, you can just open up the sidebar menu on the screen, which you can access from a little arrow on the right-hand side of the screen, and just click Report Screenshot, and then you could pause, move to that next treatment site, and then at the end of that second treatment site, you could just pause and close out. And so this is going to create those screenshots and insert those into the timeline in the RT summary in ARIA, and then it’s also going to insert those into the AlignRT report. So you’d have one screenshot from each site on the single report. Now, bear in mind, this is not a full detailed report for each site. It’s just a screenshot. So if you or your physician prefers to have a full detailed report for each site, that’s also fairly easy to do. And in order to do that, if you’re treating someone with, once again, two sites, at the end of that first site, you would just simply pause, close out of AlignRT, move to the next treatment site, and then reopen AlignRT. And I know for us in ARIA, if I move to that second site, it auto-launches the correlating site anyway in AlignRT, so it’s a little bit even less that we’re having to click on. But this is going to give you a full detailed report for each site for the physician to be able to review and approve, and then as well, all that’s going to be inserted in the timeline in the RT summary in ARIA in chronological order with the timestamps. So these are some of the main highlights and the features of the AlignRT reports that I have experienced up to this point.

And in comparison with our previously used system of just simply typing the values into our SGRT document at the completion of treatment from that paused AlignRT screen, the AlignRT report that is generated with the OIS report module is a much more detailed document for our patients’ records, and as well, it provides substantiating documentation to assist with our billing justification. So with the new billing changes that we’ve seen in 2026, and with the elimination of several of our previously used codes, it’s become imperative to show justification if charging that higher treatment level charge, that 77412 charge. So performing active motion management is not only best practice for our patients to ensure that they are in the correct position throughout the entire treatment, but it’s also one of the best ways to be able to provide justification of charging that 77412 charge. Therefore, practices are trying to find the best ways of being able to show supporting documentation that they’re performing active motion management. Especially if undergoing an audit, if they are reviewing and pulling specific charges, it is crucial to be able to show not only the medical necessity of performing active motion management, but also the documentation and evidence that we have been performing active motion management for our patients.

As one way of doing this, some sites are now starting to capture screenshots after they take their imaging every day. So they do their images, apply the shifts, capture the position in AlignRT, which once again zeros those deltas out, shows the patient’s in the right position. Then they could toggle beam control on, and then open up the sidebar menu and click Report Screenshot. So it’s just one additional click. It takes just a couple of seconds, but this is going to insert that screenshot into that AlignRT report. So you’d have two screenshots in that report. You’d have the one showing from the beginning that the patient’s in the correct position at the start of treatment, and then you’d have the one that’s automatically fed through at the end, showing that the patient was in the correct position at the end of treatment as well. And if beam control is toggled on, that’s reflected in that initial screenshot, so you’d be able to see that not only was the patient in the correct position at the start of treatment and at the end of treatment, but that beam control was toggled on, therefore performing active motion management. And so it’s just another option. And then as well, all that would be inserted into the timeline in the RT summary in ARIA. So if you opened up that timeline, you’d actually have a visual layout in chronological order with the timestamps of everything we had done for that patient for the day. You’d be able to look at it and visually see this is where we did our initial imaging, and then we took that screenshot. Patient’s now in the correct position. Beam control is active. Then we did our treatment. The final screenshot, patient’s still in the correct treatment position, and then the AlignRT report.

So it would definitely be another option and helpful tool to show that we’re actively monitoring the patient’s position throughout their entire treatment. With the AlignRT OIS report module, I do feel now that we have the tools, if necessary, to be able to show supporting documentation of performing active motion management. I said in the reports themselves, we have the timestamps of that monitoring session time, which correlates with what is in our RT summary in ARIA. We have the statement that automatically states the patient’s being tracked throughout treatment, but that we can customize to state the patient’s being tracked with active motion management. We have the ability of capturing those screenshots, showing that the patient’s in the correct position at the start and at the end of treatment with beam control active. And then we even have, if we choose, the ability to be able to include in the configuration of our report that patient monitoring graph, which shows that we’re tracking that patient’s treatment throughout the entire procedure, and if that patient happens to move and the deltas are out of tolerance and therefore beam is held, that’s reflected in that as well.

So with all of these, I do feel now that we are able to show the evidence of performing active motion management and therefore the justification of that higher treatment level charge. The AlignRT OIS report module has been a very useful tool for us to help to maintain precise records, eliminate the need for someone to have to manually enter in data after each treatment, eliminated the risk of human error, so now we’re more streamlined, more efficient, more accurate, and we do have, if needed, any necessary documentation and records for reimbursement justification. So once again, thank you for giving me your time and allowing me to share my experience with the AlignRT OIS report module.